Obtaining ANRE licenses for Romania
And
EWRC licenses for Republic of Bulgaria
• ANRE A1 certificate – A1 type certificate carries out tests/measurements on low voltage
electrical equipment and installations, according to the legal regulations in the field,
including technical norms PE 116/1994, respectively NTE 002/03/00
electrical equipment and installations, according to the legal regulations in the field,
including technical norms PE 116/1994, respectively NTE 002/03/00
• ANRE A2 certificate – A2 type certificate carries out tests/measurements on low and
medium voltage electrical equipment and installations, according to legal regulations in
the field, including technical norms PE 116/1994, respectively NTE 002/03/00
medium voltage electrical equipment and installations, according to legal regulations in
the field, including technical norms PE 116/1994, respectively NTE 002/03/00
• ANRE B certificate – Type B certificate gives you the necessary skills to design and
execute the designs for:
– Exterior/interior electrical installations related to civil premises/buildings and
industrial buildings.
– Installations for low voltage use.
– Aerial and underground electrical connections, single-phase and three-phase, at a
nominal voltage of 0.4 kV.
– Low-voltage connection installation intended for the supply of electricity to a single
place of consumption, executed from the low-voltage network or the
switchboard/distribution box of the transformer station.
– Execution, verification, the measurements of earthing sockets, grounding and
lightning protection installations related to civil and industrial buildings.
– Performs tests/measurements on low-voltage electrical equipment and installations,
according to legal regulations in the field.
– Maintenance work on pedestrian and road street lighting, temporary festive and
ornamental or festive ornamental, connected to public electrical installations.
– Performs tests/measurements on low-voltage electrical equipment and installations.
• The competences of the ANRE certificates of type C1A and C2A:
The C1A type certificate grants design competence for:
The C2A type certificate grants execution competence for:
– External/internal electrical installations related to civil and industrial
premises/buildings.
– External/internal electrical installations related to industrial premises/buildings.
– Installations for low/medium voltage use.
– Aerial and underground electrical connections, single-phase and three-phase, at
a nominal voltage of 0.4 kV.
– Low-voltage connection installation intended for the supply of electricity to a
single place of consumption, executed from the low-voltage network or the
switchboard/distribution box of the transformer station.
– Execution, verification, measurement of earthing sockets, grounding and
lightning protection installations related to civil and industrial buildings and in
electrical distribution networks.
– Maintenance works on pedestrian and road street lighting fixtures, temporary
festive and ornamental or festive ornamental, connected to public electrical
installations, in compliance with the provisions of Art. 54 of the commercial
company attestation regulation.
– Power lines with nominal voltages of 0.4 kV ÷ 20 kV overhead and/or
underground.
– Medium voltage substations (supply points, connection points), including related
cells.
– Aerial and/or underground electric public lighting networks.
– Electricity supply networks of housing complexes.
– Related weak current electrical installations (secondary circuits).
– Stationary storage batteries, power factor compensation electrical installations.
– Optical fiber cable installations for signal transmission.
– Measurement of insulation resistance and circuit continuity, measurement of
contact resistance at PT.
– Protection and measurement installations.
– Checks and tests of medium and low voltage electrical equipment and
installations, related to electrical distribution networks and transformer stations.
• The competences of the ANRE certificates of type C1B and C2B:
The C1B type certificate grants design competence for :
The C2B type certificate grants execution competence for:
– External/internal electrical installations related to civil premises/buildings.
– External/internal electrical installations related to industrial premises/buildings.
– Aerial and underground electrical connections, single-phase and three-phase, at a
nominal voltage of 0.4 kV.
– Low-voltage connection installation intended for the supply of electricity to a single
place of consumption, executed from the low-voltage network or the
switchboard/distribution box of the transformer station.
– Execution, verification, measurement of earthing sockets, grounding and lightning
protection installations related to civil and industrial buildings and in electrical
distribution networks.
– Maintenance work on pedestrian and road street lighting fixtures, temporary festive
and ornamental or festive ornamental, connected to public electrical installations, in
compliance with the provisions of Art. 54, from the commercial company attestation
procedure.
– Aerial and/or underground power lines, with nominal voltages of 0.4 kV ÷ 110 kV.
– Medium voltage substations (supply points, connection points), including related
cells.
I- Installations for use.
– Aerial and/or underground electric public lighting networks.
– Electric power supply networks of housing complexes.
– Guard wire with optical fiber included on the 110 kV LEA.
– Optical fiber cable installations for signal transmission.
– Low current electrical installations (secondary circuits).
O- Command, control and relay protection installations.
– Stationary storage batteries, power factor compensation electrical installations.
– Measurement of insulation resistance and circuit continuity, measurement of
contact resistance at PT.
– Checks and tests of high, medium and low voltage electrical equipment and
installations, related to electrical distribution networks and transformer stations.
• ANRE PDIB and EDIB certificate
Competences of ANRE PDIB type certificates :
Pressure level: medium, reduced and low
Designing installations for the use of Natural Gas/Biogas/Biomethane.
Competences of ANRE EDIB type certificates :
Pressure level: medium, reduced and low
Execution of installations for the use of Natural Gas/Biogas/Biomethane.
• ANRE PDSB and EDSB certificate :
Competences of ANRE PDSB certificates :
Pressure level : no limitations
Design of natural gas distribution systems, including closed distribution systems.
Installation design related to biogas/biomethane production/storage activity.
Competences of ANRE EDSB type certificates :
Pressure level : no limitations
Execution of natural gas distribution systems, including closed distribution systems.
Execution of installations related to the production/storage activity of
biogas/biomethane.